Cell and Battery Test Solutions
Battery systems are used in many critical applications such as transport, renewable energy, emergency lighting, medical devices, uninterruptible power supplies and cordless power tools. As the areas of use of rechargeable batteries expand, safety, performance, actual capacity and long-life criteria become technically vital.
With the cell and battery testing services we offer in this context, we analyse your products in accordance with international standards, measure their performance and verify their reliability.
• Battery capacity measurement (Ah / mAh verification)
• Internal resistance and cell health analyses
• Charge–discharge performance tests
• Cycle life and ageing tests
• Voltage stability measurement under load
• Thermal behaviour and heat resistance tests
• Safety and protection circuit verification
• BMS function tests
• Cell matching and balance analyses
• Battery pack performance verification
• Fault detection and weak cell analysis
• Application-specific stress tests
• Reporting and delivery of technical test outputs
Product Testing and Certifications
Testing Services
Accumulator, cell and battery tests
BMS tests
Capacitor tests
Life-cycle tests
Cut-out control tests
Balance tests
Climatic chamber tests
Test Capacity Details
Test capacity: up to 100V / 400A
Climatic chamber range: -40°C to +100°C
Test machines: 19 units
Test channels: 130 units
Product Management Competencies
Different product designs every year,
Material management system,
Battery system design,
3D battery mechanical design,
Prototyping and production with 3D printers,
Label design, printing and marking services for private label brands,
Battery pack design (more than 40 ready-made schematics, with customisation options available),
Preparation of production assembly files and product datasheets,
Robot, drone, e-bike, AGV, healthcare, military and industrial battery designs,
BMS integration.
| Battery Chemistry | Standard Number | Standard Title |
|---|---|---|
| Li-ion | EN 62620:2015 | Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary lithium cells and batteries for use in industrial applications |
| Nickel-Cadmium (Ni-Cd) | IEC 61951-1:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 1: Nickel-Cadmium |
| Nickel-Metal Hydride (Ni-MH) | IEC 61951-2:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 2: Nickel-Metal Hydride |
| Lead-Acid | IEC 61056-1:2012 | General purpose lead-acid batteries (valve-regulated types) – Part 1: General requirements, functional characteristics – Methods of test |
All Our Test Capabilities
| # | Test Category | Test Name | Test Method | Product Under Test | Internal / External Lab |
|---|---|---|---|---|---|
| BMS Tests | |||||
| 1 | Functional/Safety | UVP Under Voltage Protection Test | General | BMS | Internal |
| 2 | Functional/Safety | OVP Over Voltage Protection Test | General | BMS | Internal |
| 3 | Functional/Safety | OLP Over Load Protection Test | General | BMS | Internal |
| 4 | Functional/Safety | OCP Over Current Protection Test | General | BMS | Internal |
| 5 | Functional/Safety | SCP Short Circuit Protection Test | General | BMS | Internal |
| 6 | Functional/Safety | OTP Over Temperature Protection Test | General | BMS | Internal |
| 7 | Functional/Safety | UTP Under Temperature Protection Test | General | BMS | Internal |
| 8 | Functional/Safety | Cell Balancing Test | General | BMS | Internal |
| 9 | Functional/Safety | Reverse Polarity Protection Test | General | BMS | Internal |
| Battery Electrical Tests | |||||
| 10 | Electrical/Performance | Charge & Discharge Test | IEC 61960-3 | Cell / Battery | Internal |
| 11 | Electrical/Performance | Charge & Discharge Test at Different Temperatures | IEC 61960-3 | Cell / Battery | Internal |
| 12 | Electrical/Performance | Capacity Test | General | Cell / Battery | Internal |
| 13 | Electrical/Performance | Capacity Loss Test | IEC 61960-3 | Cell / Battery | Internal |
| 14 | Electrical/Performance | Capacity at Different Temperatures Test | IEC 61960-3 | Cell / Battery | Internal |
| 15 | Electrical/Performance | Life Cycle Test | General | Cell / Battery | Internal |
| 16 | Electrical/Performance | C-Rate Test | General | Cell / Battery | Internal |
| 17 | Electrical/Performance | ACIR Internal Resistance Test | IEC 61960-3 | Cell / Battery | Internal |
| 18 | Electrical/Performance | DCIR Internal Resistance Test | IEC 61960-3 | Cell / Battery | Internal |
| 19 | Electrical/Performance | Continuous and Inrush Current Tests | General | Cell / Battery | Internal |
| 20 | Electrical/Performance | CF (Crest Factor) Test | General | Cell / Battery | Internal |
| 21 | Electrical/Safety | Forced Discharge Test | IEC 62133-2 UN38.3 UL1642 |
Cell / Battery | Internal |
| 22 | Electrical/Safety | External Short Circuit Test | IEC 62133-2 IEC 62619 UN38.3 UL1642 |
Cell / Battery | Internal |
| 23 | Electrical/Safety | Over Charging Test | IEC 62133-2 IEC 62619 UN38.3 UL1642 |
Cell / Battery | Internal |
| Environmental Condition Tests | |||||
| 24 | Environmental Condition | Low Temperature Test | MIL-STD-810 E/F/G DO-160E |
Cell / Battery / BMS | Internal |
| 25 | Environmental Condition | High Temperature Test | MIL-STD-810 E/F/G/H DO-160E |
Cell / Battery / BMS | Internal |
| 26 | Environmental Condition | Low Temperature Storage Test | MIL-STD-810 E/F/G DO-160E |
Cell / Battery / BMS | Internal |
| 27 | Environmental Condition | High Temperature Storage Test | MIL-STD-810 E/F/G/H DO-160E |
Cell / Battery | Internal |
| 28 | Environmental Condition | Thermal Shock Test | MIL-STD-810 E/F/G DO-160E |
Cell / Battery | Internal |
| 29 | Environmental Condition | Humidity Test | MIL-STD-810 E/F/G DO-160E |
Cell / Battery | Internal |
| 30 | Environmental Condition | Immersion Test | MIL-STD-810 E/F/G DO-160E |
Cell / Battery | Internal |
| 31 | Environmental Condition | Dust Test | MIL-STD-810 E/F/G DO-160E |
Cell / Battery | Internal |
| 32 | Environmental Condition | Sand Test | MIL-STD-810 E/F/G DO-160E |
Battery | External |
| 33 | Environmental Condition | Salt Spray Test | MIL-STD-810 E/F/G DO-160E |
Battery | External |
| Mechanical Tests | |||||
| 34 | Mechanical | Vibration Test | MIL-STD-810 F/G/H DO-160E IEC 62133-2 UN38.3 UL1642 |
Cell / Battery | External |
| 35 | Mechanical | Transit Drop Test | MIL-STD-810 IEC 62133-2 IEC 62619 IATA PI 96X |
Cell / Battery | External |
| 36 | Mechanical | Mechanical Shock Test | MIL-STD-810 E/F/G IEC 62133-2 UN38.3 UL1642 |
Cell / Battery | External |
| 37 | Mechanical | Impact Test | IEC 62133-2 IEC 62619 UN38.3 UL1642 |
Cell / Battery | External |
| 38 | Mechanical | Crush Test | IEC 62133-2 UN38.3 UL1642 |
Cell / Battery | External |
| 39 | Mechanical | Explosion Test | UL1642 | Cell / Battery | External |
| EMC Tests | |||||
| 40 | EMC/EMI | Radiated Immunity | MIL-STD-461 IEC 61000-4-3 |
Battery / Charger | External |
| 41 | EMC/EMI | Conducted Immunity | MIL-STD-461 IEC 61000-4-6 |
Charger | External |
| 42 | EMC/EMI | Electrostatic Discharge (ESD) | MIL-STD-461 IEC 61000-4-2 |
Battery / Charger | External |
| 43 | EMC/EMI | Electrical Fast Transient/Burst Immunity (EFT/Burst) | MIL-STD-461 IEC 61000-4-4 |
Charger | External |
| 44 | EMC/EMI | Surge Immunity | MIL-STD-461 IEC 61000-4-5 |
Charger | External |
| 45 | EMC/EMI | Voltage Dips, Short Interruptions and Voltage Variations Immunity | MIL-STD-461 IEC 61000-4-11 |
Charger | External |
| 46 | EMC/EMI | Conducted Emission | MIL-STD-461 EN55032 CISPR32 |
Battery / Charger | External |
| 47 | EMC/EMI | Conducted Emission | MIL-STD-461 EN55022 CISPR22 |
Battery / Charger | External |
| 48 | EMC/EMI | Harmonic Current Emission | MIL-STD-461 IEC 61000-3-2 |
Charger | External |
| Specific Tests | |||||
| 49 | Electrical | Load Analysis | General | Load | Internal |
| 50 | Electrical / Safety / Environmental / Mechanical | Specific Performance | General | Cell / Battery / BMS / Charger | Internal |
| 51 | Electrical / Safety / Environmental / Mechanical | Stress Tests | General | Cell / Battery / BMS / Charger | Internal |
| # | Standard Code | Standard Description |
|---|---|---|
| 1 | MIL-STD-810 | Military Standard: Environmental Engineering Considerations and Laboratory Tests |
| 2 | MIL-STD-461 | Military Standard: Electromagnetic Interference Characteristics Requirements For Equipment |
| 3 | IEC/EN 62133-2 | Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications - Part 2: Lithium Systems |
| 4 | IEC/EN 62619 | Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Secondary Lithium Cells and Batteries, for Use in Industrial Applications |
| 5 | IEC/EN 62620 | Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes – Secondary Lithium Cells and Batteries for Use in Industrial Applications |
| 6 | IEC/EN 61960-3 | Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Secondary Lithium Cells and Batteries for Portable Applications - Part 3: Prismatic and Cylindrical Lithium Secondary Cells, and Batteries Made From Them |
| 7 | IEC/EN 62281 | Safety of Primary and Secondary Lithium Cells and Batteries During Transport |
| 8 | IEC/EN 63056 | Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Secondary Lithium Cells and Batteries for Use in Electrical Energy Storage Systems |
| 9 | IEC/EN 62485-5 | Safety Requirements for Secondary Batteries and Battery Installations - Part 5: Safe Operation of Stationary Lithium Ion Batteries |
| 10 | IEC/EN 50604-1 | Secondary Lithium Batteries for Light EV (Electric Vehicle) Applications - Part 1: General Safety Requirements and Test Methods |
| 11 | UN38.3 | Transport Of Lithium Metal, Lithium Ion and Sodium Ion Batteries |
| 12 | UL2054 | Household and Commercial Batteries |
| 13 | UL2271 | Batteries For Use In Light Electric Vehicle (LEV) Applications |
| 14 | UL2580 | Batteries For Use In Electric Vehicles |
| 15 | UL1642 | Standard For Safety Lithium Batteries |
| 16 | UL1973 | Batteries for Use In Stationary and Motive Auxiliary Power Applications |
| 17 | MSDS | Material Safety Data Sheet |