Cell and Battery Test Solutions

Battery systems are used in many critical applications such as transport, renewable energy, emergency lighting, medical devices, uninterruptible power supplies and cordless power tools. As the areas of use of rechargeable batteries expand, safety, performance, actual capacity and long-life criteria become technically vital.

With the cell and battery testing services we offer in this context, we analyse your products in accordance with international standards, measure their performance and verify their reliability.

• Battery capacity measurement (Ah / mAh verification)
• Internal resistance and cell health analyses
• Charge–discharge performance tests
• Cycle life and ageing tests
• Voltage stability measurement under load
• Thermal behaviour and heat resistance tests
• Safety and protection circuit verification
• BMS function tests
• Cell matching and balance analyses
• Battery pack performance verification
• Fault detection and weak cell analysis
• Application-specific stress tests
• Reporting and delivery of technical test outputs

Product Testing and Certifications

Testing Services

  • Accumulator, cell and battery tests

  • BMS tests

  • Capacitor tests

  • Life-cycle tests

  • Cut-out control tests

  • Balance tests

  • Climatic chamber tests

Test Capacity Details

  • Test capacity: up to 100V / 400A

  • Climatic chamber range: -40°C to +100°C

  • Test machines: 19 units

  • Test channels: 130 units

Product Management Competencies

  • Different product designs every year,

  • Material management system,

  • Battery system design,

  • 3D battery mechanical design,

  • Prototyping and production with 3D printers,

  • Label design, printing and marking services for private label brands,

  • Battery pack design (more than 40 ready-made schematics, with customisation options available),

  • Preparation of production assembly files and product datasheets,

  • Robot, drone, e-bike, AGV, healthcare, military and industrial battery designs,

  • BMS integration.

Battery Chemistry Standard Number Standard Title
Li-ion EN 62620:2015 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary lithium cells and batteries for use in industrial applications
Nickel-Cadmium (Ni-Cd) IEC 61951-1:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 1: Nickel-Cadmium
Nickel-Metal Hydride (Ni-MH) IEC 61951-2:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes – Secondary sealed cells and batteries for portable applications – Part 2: Nickel-Metal Hydride
Lead-Acid IEC 61056-1:2012 General purpose lead-acid batteries (valve-regulated types) – Part 1: General requirements, functional characteristics – Methods of test

All Our Test Capabilities

List of Test Capabilities
# Test Category Test Name Test Method Product Under Test Internal / External Lab
BMS Tests
1 Functional/Safety UVP Under Voltage Protection Test General BMS Internal
2 Functional/Safety OVP Over Voltage Protection Test General BMS Internal
3 Functional/Safety OLP Over Load Protection Test General BMS Internal
4 Functional/Safety OCP Over Current Protection Test General BMS Internal
5 Functional/Safety SCP Short Circuit Protection Test General BMS Internal
6 Functional/Safety OTP Over Temperature Protection Test General BMS Internal
7 Functional/Safety UTP Under Temperature Protection Test General BMS Internal
8 Functional/Safety Cell Balancing Test General BMS Internal
9 Functional/Safety Reverse Polarity Protection Test General BMS Internal
Battery Electrical Tests
10 Electrical/Performance Charge & Discharge Test IEC 61960-3 Cell / Battery Internal
11 Electrical/Performance Charge & Discharge Test at Different Temperatures IEC 61960-3 Cell / Battery Internal
12 Electrical/Performance Capacity Test General Cell / Battery Internal
13 Electrical/Performance Capacity Loss Test IEC 61960-3 Cell / Battery Internal
14 Electrical/Performance Capacity at Different Temperatures Test IEC 61960-3 Cell / Battery Internal
15 Electrical/Performance Life Cycle Test General Cell / Battery Internal
16 Electrical/Performance C-Rate Test General Cell / Battery Internal
17 Electrical/Performance ACIR Internal Resistance Test IEC 61960-3 Cell / Battery Internal
18 Electrical/Performance DCIR Internal Resistance Test IEC 61960-3 Cell / Battery Internal
19 Electrical/Performance Continuous and Inrush Current Tests General Cell / Battery Internal
20 Electrical/Performance CF (Crest Factor) Test General Cell / Battery Internal
21 Electrical/Safety Forced Discharge Test IEC 62133-2
UN38.3
UL1642
Cell / Battery Internal
22 Electrical/Safety External Short Circuit Test IEC 62133-2
IEC 62619
UN38.3
UL1642
Cell / Battery Internal
23 Electrical/Safety Over Charging Test IEC 62133-2
IEC 62619
UN38.3
UL1642
Cell / Battery Internal
Environmental Condition Tests
24 Environmental Condition Low Temperature Test MIL-STD-810 E/F/G
DO-160E
Cell / Battery / BMS Internal
25 Environmental Condition High Temperature Test MIL-STD-810 E/F/G/H
DO-160E
Cell / Battery / BMS Internal
26 Environmental Condition Low Temperature Storage Test MIL-STD-810 E/F/G
DO-160E
Cell / Battery / BMS Internal
27 Environmental Condition High Temperature Storage Test MIL-STD-810 E/F/G/H
DO-160E
Cell / Battery Internal
28 Environmental Condition Thermal Shock Test MIL-STD-810 E/F/G
DO-160E
Cell / Battery Internal
29 Environmental Condition Humidity Test MIL-STD-810 E/F/G
DO-160E
Cell / Battery Internal
30 Environmental Condition Immersion Test MIL-STD-810 E/F/G
DO-160E
Cell / Battery Internal
31 Environmental Condition Dust Test MIL-STD-810 E/F/G
DO-160E
Cell / Battery Internal
32 Environmental Condition Sand Test MIL-STD-810 E/F/G
DO-160E
Battery External
33 Environmental Condition Salt Spray Test MIL-STD-810 E/F/G
DO-160E
Battery External
Mechanical Tests
34 Mechanical Vibration Test MIL-STD-810 F/G/H
DO-160E
IEC 62133-2
UN38.3
UL1642
Cell / Battery External
35 Mechanical Transit Drop Test MIL-STD-810
IEC 62133-2
IEC 62619
IATA PI 96X
Cell / Battery External
36 Mechanical Mechanical Shock Test MIL-STD-810 E/F/G
IEC 62133-2
UN38.3
UL1642
Cell / Battery External
37 Mechanical Impact Test IEC 62133-2
IEC 62619
UN38.3
UL1642
Cell / Battery External
38 Mechanical Crush Test IEC 62133-2
UN38.3
UL1642
Cell / Battery External
39 Mechanical Explosion Test UL1642 Cell / Battery External
EMC Tests
40 EMC/EMI Radiated Immunity MIL-STD-461
IEC 61000-4-3
Battery / Charger External
41 EMC/EMI Conducted Immunity MIL-STD-461
IEC 61000-4-6
Charger External
42 EMC/EMI Electrostatic Discharge (ESD) MIL-STD-461
IEC 61000-4-2
Battery / Charger External
43 EMC/EMI Electrical Fast Transient/Burst Immunity (EFT/Burst) MIL-STD-461
IEC 61000-4-4
Charger External
44 EMC/EMI Surge Immunity MIL-STD-461
IEC 61000-4-5
Charger External
45 EMC/EMI Voltage Dips, Short Interruptions and Voltage Variations Immunity MIL-STD-461
IEC 61000-4-11
Charger External
46 EMC/EMI Conducted Emission MIL-STD-461
EN55032
CISPR32
Battery / Charger External
47 EMC/EMI Conducted Emission MIL-STD-461
EN55022
CISPR22
Battery / Charger External
48 EMC/EMI Harmonic Current Emission MIL-STD-461
IEC 61000-3-2
Charger External
Specific Tests
49 Electrical Load Analysis General Load Internal
50 Electrical / Safety / Environmental / Mechanical Specific Performance General Cell / Battery / BMS / Charger Internal
51 Electrical / Safety / Environmental / Mechanical Stress Tests General Cell / Battery / BMS / Charger Internal
List of Standard Options
# Standard Code Standard Description
1 MIL-STD-810 Military Standard: Environmental Engineering Considerations and Laboratory Tests
2 MIL-STD-461 Military Standard: Electromagnetic Interference Characteristics Requirements For Equipment
3 IEC/EN 62133-2 Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made From Them, for Use in Portable Applications - Part 2: Lithium Systems
4 IEC/EN 62619 Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Secondary Lithium Cells and Batteries, for Use in Industrial Applications
5 IEC/EN 62620 Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes – Secondary Lithium Cells and Batteries for Use in Industrial Applications
6 IEC/EN 61960-3 Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Secondary Lithium Cells and Batteries for Portable Applications - Part 3: Prismatic and Cylindrical Lithium Secondary Cells, and Batteries Made From Them
7 IEC/EN 62281 Safety of Primary and Secondary Lithium Cells and Batteries During Transport
8 IEC/EN 63056 Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Secondary Lithium Cells and Batteries for Use in Electrical Energy Storage Systems
9 IEC/EN 62485-5 Safety Requirements for Secondary Batteries and Battery Installations - Part 5: Safe Operation of Stationary Lithium Ion Batteries
10 IEC/EN 50604-1 Secondary Lithium Batteries for Light EV (Electric Vehicle) Applications - Part 1: General Safety Requirements and Test Methods
11 UN38.3 Transport Of Lithium Metal, Lithium Ion and Sodium Ion Batteries
12 UL2054 Household and Commercial Batteries
13 UL2271 Batteries For Use In Light Electric Vehicle (LEV) Applications
14 UL2580 Batteries For Use In Electric Vehicles
15 UL1642 Standard For Safety Lithium Batteries
16 UL1973 Batteries for Use In Stationary and Motive Auxiliary Power Applications
17 MSDS Material Safety Data Sheet

Contact Us

Fill in the form for a customised battery solution, testing services, technical support or a price quote; our expert team will get back to you as soon as possible.

Write to Us